- User Manual Fluke Dtx-1800 Download Fluke dtx user manual Download Link Fluke Networks DTX-1800 CableAnalyzer certifies copper cabling networks at speeds up to 10 gigabits. This text is to give a brief introduction of Fluke Networks DTX Compact OTDR. 2 headphones 2 ac charger, USB Interface Cable, user manual and carrying case.
- Users Manual 2. The DTX-1800 and DTX-1200 store up to 4,000 Autotest results, including graphical data, on a 128 MB removable memory card. (See page 54 for storage recommendations.). Runs for at least 12 hours on the rechargeable lithium ion battery pack. Smart remote with optional fiber module can be used with Fluke Networks OF-500.
- Fluke Dtx 1800 User Manual Pdf
- Fluke Networks Dtx-1800
- Fluke Dtx 1800 Calibration
- Fluke Networks Dtx-1800 User Manual 2017
The DTXGKIT, together with DTX CableAnalyzer, is the first field . Interface Cable (Mini-B), Serial RS Cable (IEEE to DB-9), User Manual. DTX Measuring Instruments pdf manual download. Also for: Dtx-lt, for Fluke DTX Measuring Instruments Fluke DTX-CLT CertiFiber User Manual. View and Download Fluke DTX technical reference handbook online. CableAnalyzer. Measuring Instruments Fluke User Manual. Earth ground .
Author: | Nelkis Gardami |
Country: | Sudan |
Language: | English (Spanish) |
Genre: | History |
Published (Last): | 5 February 2006 |
Pages: | 342 |
PDF File Size: | 10.8 Mb |
ePub File Size: | 16.83 Mb |
ISBN: | 742-5-49453-359-7 |
Downloads: | 54603 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Tojagul |
Fluke DTX-1800 Technical Reference Handbook
Fluke DTX-1800 Pdf User Manuals. View online or download Fluke DTX-1800 Technical Reference Handbook. Contacting Fluke Networks 29. Unpacking 30. DTX-CLT CertiFiber 32. DTX-MFM2 Multimode Fiber Modules. Selecting Auto Or Manual OTDR Mode 168. About Launch And Receive Fibers 169. The Fluke Networks DTX-1200 CableAnalyzer with smart remote performs TIA Level III accuracy tests of copper cabling at bandwidths up to 350 MHz that comply with industry standards including TIA, ISO/IEC, EN, ANSI, and IEEE.
Page 41 Getting Acquainted Basic Features amd36f. Press Change Media to change it if necessary.
Setting Up a Job Folder The minimum level of noise considered to be a noise hit. Loss results for 3 Jumper method therefore represent only Results from the 3 Jumper fluke dtx 1800 user manual account for the loss of the fiber in the link.
Checking the Iser Status and Connect an updated tester or smart remote to a tester or fluke dtx 1800 user manual remote that needs updating, as shown in Figure or This indicates the traffic density on the network. Selecting a Cable ID Source This function fluke dtx 1800 user manual a link pulse on connections at a patch panel. The connector accepts 2. You can usually determine that other reflections are ghosts because they occur at A reflective event that is multiples of distances to connectors and they show almost no loss.
C-6 Modified 1 Jumper Method To ensure that your measurements uuser accurate and Caution repeatable, use reference test cords provided by Fluke Networks or cords of the same quality.
Fluke Dtx 1800 User Manual Pdf
DTX CableAnalyzer Users Manual, Rev. 1 | Fluke Networks
One end of each must have an SC connector. Table on page shows the pin connections for this cable. Connect the tester and smart remote together, as shown in Figure When the Fiber Characteristics is set to Default, the tester uses the values defined in the current Fiber Type. Getting Acquainted Basic Maual amd36f.
Higher ACR values mean received signals are much larger than crosstalk signals. The results described here are for an unsaved test.
Connections screen TIA reporting requirements. Install an optional SFP small form pluggable module to test fiber links.
FLUKE DTX TECHNICAL REFERENCE HANDBOOK Pdf Download.
Dry with a dry swab or wipe. The tester offers three types of compensation: Anytime you see a negative loss measurement see page Viewing the Autotest Results Refer to the appropriate measurement repeatability and consistency. A spool of cable with poor NEXT performance.
Essentials For Reliable Fiber Test Results To get reliable fiber test results, you must follow proper cleaning and referencing procedures fluke dtx 1800 user manual, in some cases, Inspect connectors with a fiber microscope, such as the use mandrels during testing.
On the Negotiation Details screen, Yes for Pin Reversal indicates a reversed pair on the link, such as wires 1 and 2 crossed. A yellow checkmark means there is a warning for the result.
The bar graph shows the space used in the current memory destination. Note Note Fluke dtx 1800 user manual on the tester and let it sit for 1 minute before setting the reference.
Certifying Fiber Optic Cabling Using the Power Meter Using the Power Meter The power meter lets you measure the optical power produced by a source such as an optical network interface card or optical test equipment.
To change the magnification, press Change To Zoom; Save the file to your Fluke Networks website or contact Fluke Networks to get hard drive.
The reference procedure sets a baseline for insertion loss, ACR-F, and dc resistance measurements. Contact Fluke Networks for more information.
Most 10 Related
D T X - E LT C a b l e A n a l y z e r
The Gold Standard in cable certification now configured to meet the specific needs of electrical installers
The DTX advantage: speed, performance and accuracy
The DTX CableAnalyzer’s powerful features, speed and ease-of-use, increases efficiency and productivity, improving your bottom line. It’s all about time – and no other tester delivers like the DTX.
•Increase productivity from day one. Intuitive interface means your technicians spend less time in training and more
time testing.
•Level IV Accuracy. Get the most accurate test results in the shortest possible time.
•Advanced time-saving diagnostics. Pinpoints the location of a failure and is the only tester that suggests corrective action, saving troubleshooting time.
•12-hour battery life. Gives you the power to complete any job.
•Professional reporting.
LinkWare™ Cable Test Management Software manages test results and produces reports in hardcopy or PDF format.
•The DTX Series future-proofs your investment, giving you a clear and simple upgrade path from the DTX-ELT to any higher performance model, including the DTX-1800.
Certification made easy
The DTX-ELT gives you a solution that streamlines every aspect of the certification job – from setup, to testing and record-fast troubleshooting, to reporting results to the customer. This newest member of Fluke Networks DTX CableAnalyzer family, the DTX-ELT is designed to meet the specific needs of electrical installers.
Troubleshooting: twice as fast
When a link fails, the DTX-ELT shows you easy-to-understand directions to identify the point of failure (distance from the tester) and the possible reason(s) for the failure. These directions not only tell you the problem, but identify corrective actions you can take to solve the problem quickly.
Instead of spending time executing trial and error corrections – and re-testing to find out whether the problem has been resolved – the technician knows exactly where to look and what to do to fix the failing link. Even if only two percent of the tested links fail, the DTX diagnostics will save you as much as two hours of labor per day to turn the failures into passes.
Enhanced user experience
Fluke Networks Dtx-1800
The DTX-ELT isn’t just a faster way to test. It cuts set-up, training and reporting times.
Extended battery life means you can do more on a single charge. And a bright color display, ample memory, and built-in talk set all contribute to overall productivity while enhancing the user experience. This all adds up to saving you time and money every day.
Enabling cable certification for electrical installers
DTX-ELT Specifications
Test Standards | • TIA Category 3 and 5e per TIA/EIA-568-B | |
• TIA Category 5 (1000BASE-T) per TIA TSB-95 | ||
• TIA Category 6 per TIA/EIA-568B.2-1 | ||
• ISO/IEC 11801 Class C, D, and E | ||
• EN 50173 Class C, D, E | ||
• ANSI TP-PMD | ||
• IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T | ||
• IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps | ||
Standard Link Interface Adapters | • Channel adapters for: TIA Category 3, 4, 5, 5e and 6: 100Ω | |
Shielded and Unshielded Twisted | • ISO/IEC Class C and D: 100Ω and 120Ω | |
Pair (STP, FTP, SSTP and UTP) data | • ISO/IEC Class E, 100Ω | |
cabling: | • Permanent Link adapter (only with the DTX-ELT PRO): Cat 6/Class E permanent link adapters with | |
centered Cat 6A test reference plug. This plug is also the test reference for Cat 6 and lower categories. | ||
The life of the plug is rated at 10,000+ insertions. The contact block can be replaced in the field with | ||
the DTX-PLA002PRP replacement parts. | ||
Speed of Autotest | • Full 2-way Autotest of Category 6 Twisted-Pair links in 20 seconds | |
Supported Tests Parameters | (The selected test standard determines the test parameters and the frequency range of the tests) | |
• Wire Map | • Length | |
• Propagation Delay | • Delay Skew | |
• DC Loop Resistance | • Insertion Loss (Attenuation) | |
• Return Loss (RL), RL @ Remote | • NEXT, NEXT @ Remote | |
• Attenuation-to-crosstalk Ratio - | • Attenuation-to-Crosstalk Ratio - | |
Near End (ACR-N), ACR-N @ Remote | Far End (ACR-F) and ACR-F @ Remote | |
• Power Sum ACR-F (PS ACR-F), PS ACR-F @ Remote | • Power Sum NEXT (PSNEXT), PSNEXT @ Remote | |
• Power Sum ACR-N (PS ACR-N), PSACR-N @ Remote | ||
Cable Tone Generator | Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The | |
tones are generated on all pairs. Frequency range of tones: 440 Hz to 831 Hz | ||
Display | 3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight. | |
Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will | |
not cause damage. | ||
Case | Soft carrying case with shoulder strap | |
Dimensions | Samsung user manual not available in english. Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal | |
Weight | 2.4 lb (1.1 kg), nominal (without adapter or module) | |
Operating Temperature | 0°C to 40°C (32°F to 104°F) | |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) | |
Operating relative humidity | 32°F to 95 °F (0°C to 35°C): 0 % to 90% | |
(% RH without condensation) | 95°F to 113°F (35°C to 45°C): 0 % to 70 % | |
Vibration | Random, 2 g, 5 Hz -500 Hz | |
Shock | 1 m drop test with and without module and adapter attached | |
Safety | CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2 | |
Pollution degree | Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 “Safety of Information Technology | |
Equipment, 1999” | ||
Altitude | Operating: 4000 m; Storage: 12000 m | |
EMC | EN 61326-1 |
Power | Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh |
• Typical battery life: 12 to 14 hours | |
• Charge time (with tester off): 4 hours (below 40 °C) | |
• AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; | |
Output 15 V dc, 1.2 A | |
• AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, | |
48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output) | |
• Memory backup power in main unit: Lithium battery | |
• Typical life of lithium battery: 5 years | |
• The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). | |
The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F). | |
Languages Supported | Nihon kohden cardiofax c. English, French, German, Spanish, Russian and Italian |
Calibration | Service center calibration period is 1 year |
Performance Specifications | Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks |
for information on measurement performance for cable with a different impedance. | |
Baseline accuracy | The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV in |
2nd Edition of IEC 61935-1 over the frequency range supported by the tester. | |
Category 6/Class E link | DTX CableAnalyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1 |
test modes (and lower link | |
categories) |
Fluke Dtx 1800 Calibration
Length for Twisted Pair Cabling
(Length specs do not include the uncertainty of the cable’s NVP Value)
Parameter | Single-ended Test | Dual-ended Test (Main and Remote) |
800 m (2600 ft) | 150 m (490 ft) | |
Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |
Accuracy | ± (1m + 4%) | ± (1m + 4%) |
Delay Skew | ||
Parameter | Twisted Pair Cabling | |
Range | 0 ns to 100 ns | |
Resolution | 1 ns | |
Accuracy | ± 10 ns | |
DC Loop Resistance Test | ||
Parameter | Twisted Pair Cabling | |
Range | O Ω to 53Ω | |
Resolution | 0.1 Ω | |
Accuracy | ± (1 Ω + 1%) | |
Overload Recovery Time | Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or | |
prolonged over-voltage. |
Ordering Information
Model Number | Description |
DTX-ELT | DTX-ELT CableAnalyzer: Includes DTX-ELT Main and Smart Remote, LinkWare PC Software, Cat 6/Class E |
Channel Adapters (2), DTX-REFMOD Reference Module, AC Chargers (2), Carrying Case, USB Interface Cable | |
(Mini-B), Getting Started Guide, Users Manual and Technical Reference Handbook CD | |
DTX-ELT PRO | DTX-ELT PRO CableAnalyzer: |
Includes DTX-ELT Main and Smart Remote, LinkWare PC Software, Cat 6A/Class EA Permanent Link Adapters | |
(2), Cat 6/Class E Channel Adapters (2), AC Chargers (2), Carrying Case, USB Interface Cable (Mini-B), Getting | |
Started Guide, Users Manual and Technical Reference Handbook CD | |
DTX-ELT Accessories | |
DTX-PLA002S, | Interface to Cat 5/5e/6 fixed cabling infrastructure with the highest accuracy through |
Permanent Link Adaptor Set | Brother mfc-240c user manual download pdf. the industry-standard, test reference plug (centered plug). |
DTX-PLCAL, | Allows the user to calibrate the Return Loss performance of the DTX-PLA002 adaptors. |
Permanent Link Adapter | |
Field Calibration Module | |
DTX-PLA002PRP, DTX-PLA002, | This item includes two replacement contact blocks for the 8-pin modular plug of the DTX-PLA002 permanent |
plug replacement parts | link adapter. |
DTX-COAX, | Troubleshoot coaxial network cabling by measuring cable length, resistance, impedance and insertion loss. |
Coax Cable Adaptor Set | |
DTX-LION, Battery | With an extra Lithium-ion battery pack you are ensured that you have with you an |
additional 12 to 14 hours of typical battery life. | |
DTX-ACUN, Universal AC Charger | Extra AC battery charger. |
N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact.
©2008 Fluke Corporation. All rights reserved. Printed in U.S.A. 6/2008 3346250 D-EN Rev A
To continue the download you need to go through the captcha: